Description: ALLEN-BRADLEY 100-K09*10 SERIES A CONTACTOR RELAY, 24VOLT, 0443B Number of normally open contacts as main contact3Number of auxiliary contacts as normally open contact1Vibration resistanceIEC 60068-2Shock resistanceIEC 60068-2Altitude, max2000 m (NN) per IEC 60947-4LifespanMechanical DC control: 15000000 opsSwitching frequency, max250 ops/h, AC-4 (approximately 200000 operations)Recommended torque10.6 lb.inWeightDC: 0.2 kgConductor cross sectionMain contact, 2 conductor: 1...2.5 mm^2 + 1...4 mm^2Protection classIP2XElectricalVoltage type for actuatingDCType of electrical connection of main circuitScrew connectionRated impulse withstand voltage (Uimp)6 kVOptional overload relaysBimetallicMain current circuit resistance2.2 mOhmPower dissipation (all circuits)0.9 W @ 400V, AC-3, IeRated filament current9 A @ 230/240V, AC-5bRated isolation voltage (Ui)IEC: 690V, UL, CSA: 600VSwitching of motor load11 A @ 400V, AC-7b (50 Hz)PackagingSingle pack (quantity of 1)Auxiliary contactsIP2XRated current (enclosed)9.8 A @ 115V, 1-phase per UL/CSARated power (enclosed)5 Hp @ 575V, 3-phase per UL/CSAAuxiliary contact configuration1 NOCapacitance, max750 µF @ short-circuit current of 10 kAGeneral purpose current (enclosed)15 A per UL/CSAOperating time, closing delay6...12 ms DC (conventional)Switching of low inductive loads20 A @ 400V, AC-7a per IEC 61095 (50 Hz)Short time withstand (Icw)96 A for 10 s, 60 °COperating time, opening delay8...12 ms with integrated diodeCoil consumption, hold-inCold 3.0 W, warm 2.6 W DC (conventional)Coil consumption, pick-upCold 3.0 W, warm 2.6 W DC (conventional)Total power dissipationDC control: 3.5 W @ 400V, AC-3, IeOperating limits, dropout(0.2...0.75) x Us @ 50 Hz, 60 Hz, 50/60 HzSwitching of lampsGas discharge lamps, open: 18 A @ 40 °C, AC-5aInsulation class of the coilClass F per IEC 60085, Class 105 insulation system per UL 508Rating for switching AC motors3-poles: 5 Hp @ 575V (AC-2, AC-3, AC-4), 3-phase (60 Hz)Switching of hermetically sealed cooling compressor motors18 A @ 400V, AC-8a (manual reset of overload release (50 Hz))Operating limits, pick-up(0.85...1.1) x Us @ 50 Hz, 60 Hz, 50/60 HzUL class K5 and RK5 fuses rating40 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14DIN fuses (gG, gL) current ratingType 2 (per IEC 60947-4-1): 20 A @ 400 V, 50 kA available fault currentCoil voltage24V (17-30)V DC diodeRated operational current (Ie)8.9 A @ 690V, Star-Delta starting (50 Hz)UL class J and CSA HRCI-J fuses rating30 A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14Switching of power transformersApparent power: 4 kVA @ 500V, AC-6a, 50 Hz (n = 30)Rated operational power (Pe)8.3 kW @ 240V, AC-1 (50 Hz), ambient temperature 40 °CSwitching of DC loads3-poles in series: 9 A @ 48/60V (Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C)Optional accessoriesFront-mount auxiliary contacts, surge suppressors, electronic timers, mechanical interlocksFeaturesMini-contactors, Uniform panel mounting dimensions, Panel mounting or mounting on 35 mm DIN Rail, Made of environmentally friendly materialsUL class CC and CSA HRCI-MISC fuses rating30 A @ 600V, 50 kA available fault current per UL 508 and CSA 22.2 No. 14
Price: 69.95 USD
Location: Metamora, Illinois
End Time: 2024-10-25T15:39:04.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Compatible Brand: Allen-Bradley
Brand: Allen-Bradley
Type: Relay
Maximum Amperage: 100 A
Color: Gray
Manufacturer Part Number: 100-K09*10
Contact Material: Plastic
Model: 100-K09*10
Compatible Model: 100-K09*10
SHELF: DCR 303
MPN: 0443B