Description: Product description: Excellent metering accuracy is higher than that of the same instrument. It is widely used in medical testing, food, petrochemical industry, environmental protection and monitoring. field. ★ Digital display measurement value ★Automatic light door, automatic zero adjustment and 100 instrument calibration ★Use original imported tungsten lamp to ensure the service life of the instrument ★ Large sample room, can hold up to 10cm cuvette Product specifications: Optical system: achromatic Czerny-Turner (1200L / mm grating) Wavelength range: 350-1020 nm Wavelength accuracy: ±2nmDigital Visible Spectrophotometer 350-1020nm Laboratory Spectrometer Equipment*Description of ryxfebruary*Product description: ★ Digital display measurement value★Automatic light door, automatic zero adjustment and 100 instrument calibration★Use original imported tungsten lamp to ensure the service life of the instrument Product specifications: Optical system: achromatic Czerny-Turner (1200L / mm grating)Wavelength range: 350-1020 nmWavelength accuracy: ±2nmSpectral bandwidth: 6nmWavelength repeatability: ≤1nmStray light: ≤0.1%T @ 360nmPhotometric accuracy: 0.5% TPhotometric repeatability: 0.2% TDrift: ≤0.2%TNoise: ≤0.3%TStability: ±0.004A / h@500nmWorking mode: T, A, CZero mode: automaticWavelength drive mode: manual wavelengthEnergy (light source): tungsten lampWeight: 10 kg The package includes: 1 x visible spectrophotometer1 x power cord1 x glass cuvette1 x instruction Precautions: 1. The instrument should be placed in a dry room. When used, it should be placed on a firm and stable workbench. The indoor lighting should not be too strong. In the hot weather, you can not use the fan to blow directly to the instrument to prevent the bulb filament from becoming bright and unstable.2. Before using the instrument, the user should first understand the structure and working principle of the instrument, as well as the functions of each control knob. Before the power is turned on, the safety performance of the instrument should be checked. The power supply wiring should be firm and the power supply should be good. The starting position of each adjustment knob should be correct, and then press the power switch.3. When the instrument has not been powered on, the meter pointer must be on the “O” engraving line. If this is not the case, you can adjust it with the calibration screw on the meter. Instrument maintenance: 1. Temperature and humidity are important factors affecting the performance of the instrument. They can cause corrosion of mechanical parts, reduce the smoothness of the metal mirror surface, cause errors or performance degradation of the mechanical parts of the instrument; cause optical components such as gratings, mirrors, focusing mirrors, etc. The aluminum film is rusted, resulting in insufficient light energy. Stray light, noise, etc., even the instrument stops working, thus affecting the life of the instrument. It should be regularly corrected during maintenance. It should have an instrument room with four seasons and constant humidity, and be equipped with constant temperature equipment, especially ground. Laboratory in the southern region2, dust and corrosive gases in the environment can also affect the flexibility of the mechanical system, reduce the reliability of various limit switches, buttons, photoelectric couplers, and also cause one of the reasons why the aluminum film corrosion of the components must be learned. Clean, protect the environment and the indoor sanitary conditions of the instrument, dustproof3. After the instrument has been used for a certain period of time, a certain amount of dust will accumulate inside. It is best to start the dust removal work by the maintenance engineer or the engineer under the guidance of the engineer, and re-tighten the radiator of each heating element. The sealed window of the box is cleaned. If necessary, calibrate the optical path, clean the mechanical parts and necessary lubrication, and finally, restore the original condition, and then perform some necessary tests, adjustments and records.PaymentDelivery detailsTerms of salesAbout usContact usPayment We accept ebay payment 。Fees such as import duties, taxes are not included in the item price or shipping costs. These charges are the buyer's responsibility.Delivery detailsShipping: 2-9 working days to: USA Terms of sales We maintain high standards of excellence and strive for hundred percent customer satisfaction. Feedback is very important to us. We hope that you contact us immediately before you give neutral or negative feedback, so that we can address your concerns. It is impossible to address issues if we do not know about them! About usYour satisfaction is our ultimate goal. We work hard to earn your trust and future business. Our certified technicians have tested each item before shipping. The unit comes with 1 year limited warranty on all manufacturing defects.a) If you receive a defective item, you may return it or ask for a discount. Please contact us within 14 days after you receive the package.b) What you returned must be intact and in its original packaging as re? u. Customer is responsible for shipping costs of the returned item.c) We will cover the cost of shipping back t with the shipping rate indicated in the registration page. We will send you a new unit or refund the full payment you paid.Thank you.Contact usBusiness Hour Business Hour: Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.Please contact us with ebay message.Please feel free to contact us if you have any questions. Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.Please contact us with ebay message.Please feel free to contact us if you have any questions.❤Highlights❤★★★Reliable Quality★★★Easy installation★★★Ideal Gift★★★🔥Feature🔥Stable characteristic, high reliabilityCharacteristic❤Premium Material❤Long Service Life❤Creative Design❤* Feature *1*Durable Material*Beautiful Appearance*Good Performance*★Features★AAAAA+ SELLER!!!TipIf you have any question , please contact us*Features*★★★Trouble-free Installation★★★Warranty3 yearsFeaturesFast shipping, Durable Material, Easy installation, Easy installation,Convenient Use,Easy OperationFeatures1stable performance,DurableCurrent RatingDoes Not ApplyItem locationCA /NJ /AustellBrandUnbrandedMPNDoes Not ApplyWavelength range350-1020 nmWavelength accuracy±2nmSpectral bandwidth6nmWavelength repeatability≤1nmStray light≤0.1%T @ 360nmPhotometric accuracy0.5% TPhotometric repeatability0.2% TDrift≤0.2%TNoise≤0.3%TStability±0.004A / h@500nmWorking modeT, A, CZero modeAutomaticEnergy (light source)Tungsten lampTypeSpectrometerOn Oct 31, 2024 at 19:29:28 PDT, seller added the following information:
Price: 222.69 USD
Location: Chino, California
End Time: 2024-12-01T03:23:26.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
❤Highlights❤: ★★★Reliable Quality★★★Easy installation★★★Ideal Gift★★★
🔥Feature🔥: Stable characteristic, high reliability
Characteristic: ❤Premium Material❤Long Service Life❤Creative Design❤
* Feature *1: *Durable Material*Beautiful Appearance*Good Performance*
★Features★: AAAAA+ SELLER!!!
Tip: If you have any question , please contact us
*Features*: ★★★Trouble-free Installation★★★
Warranty: 3 years
Features: Fast shipping, Durable Material, Easy installation, Easy installation,Convenient Use,Easy Operation
Features1: stable performance,Durable
Current Rating: Does Not Apply
Item location: CA /NJ /Austell
Brand: Unbranded
MPN: Does Not Apply
Wavelength range: 350-1020 nm
Wavelength accuracy: ±2nm
Spectral bandwidth: 6nm
Wavelength repeatability: ≤1nm
Stray light: ≤0.1%T @ 360nm
Photometric accuracy: 0.5% T
Photometric repeatability: 0.2% T
Drift: ≤0.2%T
Noise: ≤0.3%T
Stability: ±0.004A / h@500nm
Working mode: T, A, C
Zero mode: Automatic
Energy (light source): Tungsten lamp
Type: Spectrometer