Description: I over ordered for a project I had to paint my concrete water fountain, this Qt. was not used nor opened. You will receive exactly what is pictured... Forms a continuous waterproofing barrier with exceptional adhesion and reduces crack transmission for all surfaces.Can be applied on Concrete, Wood, Stone, Tiles, Interior&Exterior Cladding, Metal&Aluminium, Drywall boards, ICF blocks, RV RoofsSafe for fish, plant produce and saltwater useFor Interior, exterior, fully submerged in water and below grade applicationsEasy application with roller, brush or airless sprayer FOR STEP-BY-STEP GUIDES SPECIFIC TO YOUR PROJECT Basements Wood Surfaces Pools / Fountains Roofs / RV Roofs Concrete Surfaces Cement / Hardiebacker Board 1Prepare your space and Gather your materials• For bare concrete or water based coatings we recommend our Preparation D in order to remove any mineral deposits or efflorescence from the surface. For this you will need the following cleaners : Nu-Lift Cleaner and Stone Soap• For concrete surfaces with oil stains or grease we recommend Preparation B.For this you will need the following cleaners : Power Cleaner and Stone SoapEnsure your surfaces are fully cleaned and dried. Gather all the products and tools needed for your project.If you need assistance with which cleaners are needed for the Prep, feel free to use our live chat or call us!2Fabric ReinforcementIf you have any cracks wider than 1/4", a Fabric Reinforcement is needed to bridge the crack. Any cracks smaller than 1/4" width, SEMCO Liquid Membrane™ can be applied over it.3MaskingMask off areas that are not receiving any coating. Remove masking tape before material has fully cured.4APPLYING COATUse a 1/2" nap roller. Allow any pre-treated areas to fully dry. Apply a thin coat (0.015 inch per coat) of SEMCO Liquid Membrane™ with brush or roller over substrate including pre-treated areas. Once you can walk on the surface and not get any residue on your shoe or feet or cannot leave a fingerprint impression it is ready to re-coat. Apply another thin coat of SEMCO Liquid Membrane™ in an alternate direction over the first coat of SEMCO Liquid Membrane™. Let topcoat dry to the touch, approximately 1–2 hours at 70 °F (21 °C) and 50% RH. When last coat has dried to the touch, inspect final surface for pinholes, voids, thin spots or other defects.SEMCO Liquid Membrane™ will dry to a lighter color when it’s dry to touch. Use additional SEMCO Liquid Membrane™ to seal the defects. Required total thickness is 0.03 - 0.04 inches for non submerged applications.5Curing TimeCuring time depends on temperature, humidity and airflow, however typically initial cure is within 6 - 7 days as per specific product recommendations. Avoid contact with water during the curing period.6Additional Information• It is not recommended to apply any of our products to green concrete. Fresh concrete should be allowed to cure for a minimum of 28 days.• For clean up use warm water to clean brush or roller right after use.• For optimal bonding we highly recommend preparing the surface as mentioned above for best results.• Stir up the product well before use in order to mix up the color pigments.• Avoid application in direct sun light in the afternoon or temperatures of over 85F as it might cause the product to dry too fast before it can adhere to the substrate• Suitable for light foot traffic.For heavy foot traffic or vehicle traffic, we recommend using SEMCO Titan Shield.• It can not be applied to wet substrates or substrates still containing moisture, else it will not cure correctly and stay tacky. Max. rest moisture in substrate can be up to 3%. If you are unsure about the moisture content, have it measured prior to application.• Ensuring that a surface is pH balanced before applying a coating is crucial for optimal adhesion and performance. Therefore we recommend our preparation methods for optimal adhesion. We do not recommend acid washes.• For applications where the product is fully submerged, 3 coats @20mil each is required and allow a curing time of minimum 6-7 days.Also application must coat entire surface to above the waterline.• Application on non porous surfaces such as metal or fiberglass : Apply thin coats as this will allow for the product to cure faster.• Cure times are displayed in our curing chart. However if coats have been applied too thick, the surface might feel tacky. This is a sign of trapped moisture. If you have left over product, apply a very thin coat over the entire surface. The surface needs to be fully cured and hard before permitting water.• For applications where SEMCO Liquid Membrane™ is applied on pool plaster, extended curing times might occur as plaster holds more moisture which needs to breath out first. A slight color change may occur when being in contact with water when the product has not fully cured yet. This however will not affect the performance of the SEMCO Liquid Membrane™.• It is always advisable to apply a small test patch in an inconspicuous are to ensure adequate adhesion prior to full application.• If you have multiple containers of SEMCO Liquid Membrane™, we highly recommend to either mix them together or use one container for the last layer to get color consistency.
Price: 25 USD
Location: Las Vegas, Nevada
End Time: 2024-10-28T01:57:06.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
All returns accepted: ReturnsNotAccepted
Brand: Semco
Item Package Quantity: 1
Type: Does not apply
Size: 1 QT
Color: Hunter Green
Item Form: Liquid
Water Resistance Level: Waterproof
Country/Region of Manufacture: United States
Is Discontinued By Manufacturer: No