Description: Manufacturer: Tripp LiteModel: Tripp Lite SmartOnline UPS 500VA 300W, RM, 1U, 120VCondition: New batteries, refurbished UPSPart Number: SMART500RT1UMaximum output: 300W / 500VATypical backup time at half load: 14.6 minutes (150 Watts)Typical backup time at full load: 3.2 minutes (300 Watts)Warranty: 1 year full replacement warranty Tripp Lite SmartOnline 500VA 300W RM 120V SMART500RT1U Manual SMART500RT1U - Tripp Lite SmartOnline 500VA Specifications: Input: Rated input current (Maximum Load) 10A Nominal Input Voltage(s) Supported 120V AC UPS Input Connection Type NEMA 5-15P Input Circuit Breakers 10A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 15A 120V Input Phase Single-Phase Output: Output Volt Amp Capacity (VA) 500 Output Watt Capacity (Watts) 300 Output kW Capacity (kW) 2.4 Output Capacity Details 4.2A @ 120V. (LINE MODE) 120% @ 5 minutes; (BATTERY MODE) 120% @ 5 seconds Power Factor 0.6 Nominal Voltage Details 120V sinusoidal in line mode and 120V PWM in battery mode Frequency Compatibility 60 Hz Frequency Compatibility Details Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal. Output Voltage Regulation (Line Mode) -14%, +16% Output Voltage Regulation (Battery Mode) +/- 5% UPS Output Receptacles (Surge Suppression Only) 5 UPS outlets, 1 surge-only outlet Load Management Receptacles One switchable single-outlet 5-15R load bank Output Circuit Breakers 15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 120V Output Receptacles (6) NEMA 5-15R (1) NEMA L5-30R Individually Controllable Load Banks Yes Battery: Battery Type Valve Regulated Lead Acid (VRLA) Full Load Runtime (min.) 3 min. (300w) Half Load Runtime (min.) 14 min. (150w) Expandable Battery Runtime Supports extended runtime with optional external battery packs Expandable Runtime No DC System Voltage (VDC) 12 Battery Recharge Rate (Included Batteries) Less than 12 hours to 90% Battery Access Battery access door Internal UPS Replacement Battery Cartridge IMPORTANT BATTERY REPLACEMENT INFORMATION > Use Tripp Lite RBC12V-1U replacement battery for SMART500RT1U models with Series Number AG-03AA listed on the UPS nameplate (sold starting in 2021); For all prior versions of SMART500RT1U, use Tripp Lite RBC62-1U replacement battery; Contact Tripp Lite customer service for additional information Battery Replacement Description Hot-swappable, user replaceable batteries Voltage Regulation: Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 90 (±5%). Input voltage range of 90 to 139 Undervoltage Correction Input voltages between 90 and 105 (±5%) are boosted by 14% User Interface, Alerts & Controls: Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm Audible alarm indicates power-failure, overload and low-battery conditions LED Indicators 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status Surge / Noise Suppression: UPS AC Suppression Joule Rating 567 UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes Physical: Primary Form Factor Rackmount; Tower Included Mounting Accessory Description Included mounting brackets provide front-rail installation in 2 or 4 post racks, plus upright tower configurations Installation Form Factors Supported with Included Accessories 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower Minimum Required Rack Depth (cm) 36.32 Minimum Required Rack Depth (inches) 14.3 Primary UPS Depth (mm) 286 Primary UPS Height (mm) 44 Primary UPS Width (mm) 440 Rack Height 1U Shipping Dimensions (hwd / cm) 10.67 x 39.88 x 54.10 Shipping Dimensions (hwd / in.) 4.20 x 15.70 x 21.30 Shipping Weight (kg) 8.67 Shipping Weight (lbs.) 19.12 UPS Housing Material Steel UPS Power Module Dimensions (hwd, cm) 4.39 x 43.99 x 28.60 UPS Power Module Dimensions (hwd, in.) 1.73 x 17.32 x 11.26 UPS Power Module Weight (kg) 7.18 UPS Power Module Weight (lbs.) 15.84 Environmental: Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 48 AC Mode Efficiency Rating (100% Load) 97% AC Economy Mode Efficiency Rating (100% Load) 0.97 Operating Elevation (ft.) 6561 ft. (2000 m) above sea level Audible Noise 45 dBA maximum, front side 1m Communications: Network Management Cards WEBCARDLX Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert Communications Cable USB and DB9 cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications Network Management Card Description Network management card optional Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
Price: 209.99 USD
Location: Tonawanda, New York
End Time: 2024-09-11T05:14:47.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Type: Enterprise/Data Center UPS
Brand: Tripp Lite
Model: Tripp Lite SMART-PRO 500VA RM 1U - SMART500RT1U
MPN: SMART500RT1U
Max. Voltage-Amps: 500VA
Voltage Compatibility: 120V
Max. Wattage: 300W
Surge Energy Capacity: 567
Outlets: 7