Description: CMS8000 6 Parameter Patient MonitorIntroductionThe monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz, adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving. FunctionsStandard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis2)RESP Respiration rate(RR) Respiration waveform3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)5)TEMP T1, T2, TD6)IBP(optional) CH1:SYS,DIA,MAPCH2:SYS,DIA,MAPIBP waveform7)CO2 EtCO2(optional) InsCO2:Inspired Minimum CO2AwRR:Air Way RespirationIt has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.3)All-round monitor for adult, pediatric and neonate.4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.5)Finish all operations by keys and knobs.6)Maximum 8-channel waveform synchronous display.7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.9)Heart rate variability (HRV) analysis function10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.12)Drug concentration calculation and titration table functions.13)One-touch printing of trend graph14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary). Performance▲ECGLead mode: 3-lead or 5-leadLead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, dual-channel3-lead, single-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR: Measurement and alarm range: 15~350 bpmAccuracy: ±1 % or ±1 bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0 mV ~ +2.0 mVAccuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yes▲RESPMethod: R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range: 0~150 rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s▲NIBPMethod: OscillometryMode: Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in STAT mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:Maximal mean deviation: ±5 mmHgMaximal standard deviation: 8 mmHgOver-pressure protection:Adult mode: 297±3 mmHg Pediatric mode: 240±3 mmHg Neonatal mode: 147±3 mmHg▲SpO2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%; 0%~69%: unspecified ▲PRMeasurement and alarm range: 30 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greater▲TEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50℃Resolution: 0.1 ℃Accuracy: ±0.1 ℃▲EtCO2(Optional)Method: Sidestream or Mainstream Measuring Range: 0~150mmHgResolution:0~69 mmHg, 0.1 mmHg70~150 mmHg, 0.25 mmHgAccuracy:0~40 mm Hg ±2 mm Hg41~70 mm Hg ±5%71~100 mm Hg ±8%101~150 mm Hg ±10%AwRR Range: 2~150 rpmAwRR Accuracy: ±1BPMApnea Alarm: Yes▲IBP(OPTIONAL)Channel: dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and Alarm Range: -10~300 mmHgResolution 1 mmHgAccuracy: ±2% or 1mmHg, whichever is greater▲Power supply: 100-240V~, 50/60Hz▲Safety classification: Class I, type CF defibrillation-proof applied part Accessories1)Adult fingertip SpO2 probe (5-pin)2)Adult NIBP cuff3)NIBP extension tube4)ECG lead cable5)ECG electrode6)Temperature probe7)Power cord8)User Manual Physical characteristicDimension: 314 mm(L) × 145 mm(W) × 264 mm(H)Weight: 3.9 KgBuy safe ProductThe following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K ApprovedShipping:1). We will ship within 1 business day after your payement ;2).We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties). Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you! This product is sold worldwide, if you are using it in the United States please contact me before purchasing.
Price: 599 USD
Location: Elk Grove Village, Illinois
End Time: 2024-11-24T06:54:23.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Screen Dimensions: 12.1“
Unit Type: Unit
Technology: Digital
Model: CMS8000
Featured Refinements: Vital Signs Monitor
MPN: 69450401
Country/Region of Manufacture: China
Monitor Parameters: Blood Pressure - NIBP, ECG, O2 - SpO2, Respiratory Rate, Temperature