Description: Xantrex C60 Charge Controller 60A, 12/24V Wind Generator, Hydro and Solar Panel Xantrex C Series - C35, C40 & C60 Charge Controllers A Controller for Virtually any DC Charging Source The C40 has long been the mainstay of our charge controller line-up, its versatility and reliability have made it an industry standard. Now the C40 is joined by two companion controllers, the C35 and C60. All three of these fully solid state, microprocessor-driven controllers are UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs. Standard Features Silent Microprocessor Control All C Series controllers (C35, C40 & C60) have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently. PWM Charge Performance C Series controllers (C35, C40 & C60) all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life. 3-Stage Battery Charging All C Series controllers (C35, C40 & C60) automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation. Field Adjustable There are a number of field configurable, user adjustments for C Series controllers. C35 and C60's can only be set for 12 or 24 VDC operation. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries. DC Load Controller Mode When used as a load controller, the C Series (C40) will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable. DC Diversion Mode In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate micro hydro and wind turbine systems which need a constant load. LED Status Indicator A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers (C35, C40 & C60). UL and cUL Listed C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers (C35, C40 & C60) are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements. LCD Digital Display (Optional) CM, CMR/50, CMR/100 -A back-lit meter which continuously displays: battery voltage, DC amperage, cumulative amp hours and amp hours since last reset. CM mounts on front of C Series, C35, C40 and C60, charge controllers. The remote meters CMR/50 and CMR/100 use simple telephone type plug-in connectors. 50 ft. (15 m) or 100 ft. (30 m) cable included. If used with a wind turbine, this will only measure voltage. Temperature Compensation BTS/15 or BTS/35 Monitors battery temperature and adjusts charging voltage for maximum performance. A 15 ft. (4.5 m) or 35 ft. (11 m) cable with standard telephone type connectors is included. Warranty Two years workmanship and materials. Specifications Model C35 C40 C60 Voltage Configurations 12 VDC 24 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC Maximum PV Array Open Circuit 55 VDC 55 VDC 125 VDC 125 VDC 125 VDC 55 VDC 55 VDC Charging/Load Current @ 25 °C 35 amps DC continuous 40 amps DC continuous 60 amps DC Continuous Recommended Breaker Size With Recommended Wire Size in Conduit 60 amps DC, #6 AWG 60 amps DC, #6 AWG 60 amps DC (100% continuous duty cycle), #6 AWG (90 °C rated) General Specifications Maximum Peak Current85 amps intermittently-electronically protectedMaximum Voltage Drop 0.30 volts -charge control mode Total Current Consumption While operating - 15 ma (typical), at idle - 3 ma (tare) Charge Regulation Method Solid state, 3-stage (Bulk, Absorption and Float) Pulse Width Modulation (PWM). Regulation Adjustment Settings Charge Control Mode Setup for: Lead Acid Battery 12 Volt Configuration: Float 12.5 - 14.5 VDC Bulk 13.0 - 15.0 VDC EQ +1 VDC above Bulk 24 Volt Configuration: Float 25.0 - 29.0 VDC Bulk 26.0 - 30.0 VDC EQ +2 VDC above Bulk 48 Volt Configuration: Float 50.0 - 58.0 VDC Bulk 52.0 - 60.0 VDC EQ +4 VDC above Bulk NiCad Type Battery (VDC above adjustment setting) Float or Bulk (add 2 VDC) Float or Bulk (add 4 VDC) Float or Bulk (add 8 VDC) Load Control Mode Low Voltage Reconnect (LVR) - Subtract 1 V (for 12 VDC systems), 2V (for 24 VDC systems), and 4 V (for 48 VDC systems) from the Bulk setting. Low Voltage Disconnect (LVD) - Subtract 2 V (for 12 VDC systems), 4 V (for 24 VDC systems), and 8V (for 48 VDC systems) from Float setting. Standard Features Status Indicator Multicolor LED indicates the operating/battery voltage status Low Voltage disconnect (Load Control Mode) User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a "grace" period. Equalization Charge (Charge Control Mode) User selectable manual or automatic equalization (every 30 days) Short Circuit Protection Fully electronically protected with auto-reset Field Adjustable Control Setpoints (test points provided for high accruacy) Two user adjustable voltage setpoints for control of loads or charging sources (settings retained if battery is disconnected) Options LCD Meter Panel (CM, CMR/25 CMR/50, CMR/100) Back-lit, 2-line, 32 character, alpha numeric liquid crystal display panel for remote (CMR/XX) or front mounting (CM) on the C Series controller. CMR/25 includes 25' (7.5 m) of cable. CMR/50 includes 50' (15 m) of cable, CMR/100 includes 100' (30 m) of cable. Displays: battery voltage, DC amperage, cumulative amp hours, amp hours since last reset. External Battery Temperature Sensor (BTS/15, BTS/35) Provides automatic adjustment of the charge control setpoints to the battery temperature. BTS/15 is supplied with 15' (4.5 m) of cable, BTS/35 cable length is 35' (11 m) Physical Enclosure Type Indoor, ventilated, powder-coated steel with 3/4" and 1" knockouts Specified Temperature Range 32 to 104 °F (0 to +40 °C) Allowed Temperature Range -67 to 167 °F (-55 to +75 °C) Altitude Limit (operating) 15,000 feet (5,000 meters) Altitude Limit (non-operating) 50,000 feet (16,000 meters) Dimensions (H x W x D) C35: 8" x 5" x 2.5" (20.3 cm x 12.7 cm x 6.35 cm) C40, C60: 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm) Mounting Vertical Wall Mount Weight (Controller only) C35: 2.5 lbs (1.2 kg), C40: 3.0 lbs (1.4 kg), C60: 3.0 lbs (1.4 kg) Weight (Shipping) C35: 3.0 lbs (1.4 kg), C40: 3.5 lbs (1.6 kg), C60: 3.5 lbs (1.6 kg) Certifications UL Listed to UL 1741 and CSA 22.2 107.1-95. CE Compliant, Designed to CTIK Standards. Warranty All C35, C40 and C60 controllers are warrantied for two years against defects in workmanship and materials. Hurricane Wind Power 2019Corporate America Today2019 Best Off-Grid Renewable Energy Product Supplier - USAUP TO 50% DISCOUNTSTOP BRANDSPaymentShippingReturnsPaymentShippingReturns We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement. If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. See our other itemsThank you for visiting our Ebay store!Trace / Xantrex Auction for C60 Model only other models discussed for line comparison of PWM / Diversion load controllerShown with optional Meter see other auctions Xantrex C Series - C35, C40 & C60 Charge Controllers A Controller for Virtually any DC Charging Source The C40 has long been the mainstay of our charge controller line-up, its versatility and reliability have made it an industry standard. Now the C40 is joined by two companion controllers, the C35 and C60. All three of these fully solid state, microprocessor-driven controllers are UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs. Standard FeaturesSilent Microprocessor Control All C Series controllers (C35, C40 & C60) have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently. PWM Charge Performance C Series controllers (C35, C40 & C60) all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life. 3-Stage Battery Charging All C Series controllers (C35, C40 & C60) automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation. Field Adjustable There are a number of field configurable, user adjustments for C Series controllers. C35 and C60's can only be set for 12 or 24 VDC operation. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries. DC Load Controller Mode When used as a load controller, the C Series (C40) will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable. DC Diversion Mode In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate microhydro and wind turbine systems which need a constant load. LED Status Indicator A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers (C35, C40 & C60). UL and cUL Listed C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers (C35, C40 & C60) are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements. LCD Digital Display (Optional) CM, CMR/50, CMR/100 -A back-lit meter which continuously displays: battery voltage, DC amperage, cumulative amp hours and amp hours since last reset. CM mounts on front of C Series, C35, C40 and C60, charge controllers. The remote meters CMR/50 and CMR/100 use simple telephone type plug-in connectors. 50 ft. (15 m) or 100 ft. (30 m) cable included. If used with a wind turbine, this will only measure voltage. Temperature Compensation BTS/15 or BTS/35 Monitors battery temperature and adjusts charging voltage for maximum performance. A 15 ft. (4.5 m) or 35 ft. (11 m) cable with standard telephone type connectors is included. Warranty Two years workmanship and materials. Specifications Model C35 C40 C60 Voltage Configurations 12 VDC 24 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC Maximum PV Array Open Circuit 55 VDC 55 VDC 125 VDC 125 VDC 125 VDC 55 VDC 55 VDC Charging/Load Current @ 25 °C 35 amps DC continuous 40 amps DC continuous 60 amps DC Continuous Recommended Breaker Size With Recommended Wire Size in Conduit 60 amps DC, #6 AWG 60 amps DC, #6 AWG 60 amps DC (100% continuous duty cycle), #6 AWG (90 °C rated) General Specifications Maximum Peak Current 85 amps intermittently-electronically protected Maximum Voltage Drop 0.30 volts -charge control mode Total Current Consumption While operating - 15 ma (typical), at idle - 3 ma (tare) Charge Regulation Method Solid state, 3-stage (Bulk, Absorption and Float) Pulse Width Modulation (PWM). Regulation Adjustment Settings Charge Control Mode Setup for: Lead Acid Battery 12 Volt Configuration: Float 12.5 - 14.5 VDC Bulk 13.0 - 15.0 VDC EQ +1 VDC above Bulk 24 Volt Configuration: Float 25.0 - 29.0 VDC Bulk 26.0 - 30.0 VDC EQ +2 VDC above Bulk 48 Volt Configuration: Float 50.0 - 58.0 VDC Bulk 52.0 - 60.0 VDC EQ +4 VDC above Bulk NiCad Type Battery (VDC above adjustment setting) Float or Bulk (add 2 VDC) Float or Bulk (add 4 VDC) Float or Bulk (add 8 VDC) Load Control Mode Low Voltage Reconnect (LVR) - Subtract 1 V (for 12 VDC systems), 2V (for 24 VDC systems), and 4 V (for 48 VDC systems) from the Bulk setting. Low Voltage Disconnect (LVD) - Subtract 2 V (for 12 VDC systems), 4 V (for 24 VDC systems), and 8V (for 48 VDC systems) from Float setting. Standard Features Status Indicator Multicolor LED indicates the operating/battery voltage status Low Voltage disconnect (Load Control Mode) User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a "grace" period. Equalization Charge (Charge Control Mode) User selectable manual or automatic equalization (every 30 days) Short Circuit Protection Fully electronically protected with auto-reset Field Adjustable Control Setpoints (test points provided for high accruacy) Two user adjustable voltage setpoints for control of loads or charging sources (settings retained if battery is disconnected) Options LCD Meter Panel (CM, CMR/25 CMR/50, CMR/100) Back-lit, 2-line, 32 character, alpha numeric liquid crystal display panel for remote (CMR/XX) or front mounting (CM) on the C Series controller. CMR/25 includes 25' (7.5 m) of cable. CMR/50 includes 50' (15 m) of cable, CMR/100 includes 100' (30 m) of cable. Displays: battery voltage, DC amperage, cumulative amp hours, amp hours since last reset. External Battery Temperature Sensor (BTS/15, BTS/35) Provides automatic adjustmentt of the charge control setpoints to the battery temperature. BTS/15 is supplied with 15' (4.5 m) of cable, BTS/35 cable length is 35' (11 m) Physical Enclosure Type Indoor, ventilated, powder-coated steel with 3/4" and 1" knockouts Specified Temperature Range 32 to 104 °F (0 to +40 °C) Allowed Temperature Range -67 to 167 °F (-55 to +75 °C) Altitude Limit (operating) 15,000 feet (5,000 meters) Altitude Limit (non-operating) 50,000 feet (16,000 meters) Dimensions (H x W x D) C35: 8" x 5" x 2.5" (20.3 cm x 12.7 cm x 6.35 cm) C40, C60: 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm) Mounting Vertical Wall Mount Weight (Controller only) C35: 2.5 lbs (1.2 kg), C40: 3.0 lbs (1.4 kg), C60: 3.0 lbs (1.4 kg) Weight (Shipping) C35: 3.0 lbs (1.4 kg), C40: 3.5 lbs (1.6 kg), C60: 3.5 lbs (1.6 kg) Certifications UL Listed to UL 1741 and CSA 22.2 107.1-95. CE Compliant, Designed to CTIK Standards. Warranty All C35, C40 and C60 controllers are warrantied for two years against defects in workmanship and materials. On Oct-22-13 at 17:27:47 PDT, seller added the following information: Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application [FREE! Sellers: Add a FREE map to your listings. FREE!] (http://newage.mystoremaps.com/echo/tagLine?sid=cea073c8-fc6f-494f-9ca5-610e8850a127&tid=1) Xantrex C60 Charge Controller 60A, 12/24V Wind Generator, Hydro and Solar Panel Trace / Xantrex Auction for C60 Model only other models discussed for line comparison of PWM / Diversion load controllerShown with optional Meter see other auctions Xantrex C Series - C35, C40 & C60 Charge Controllers A Controller for Virtually any DC Charging Source The C40 has long been the mainstay of our charge controller line-up, its versatility and reliability have made it an industry standard. Now the C40 is joined by two companion controllers, the C35 and C60. All three of these fully solid state, microprocessor-driven controllers are UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs. Standard FeaturesSilent Microprocessor Control All C Series controllers (C35, C40 & C60) have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently. PWM Charge Performance C Series controllers (C35, C40 & C60) all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life. 3-Stage Battery Charging All C Series controllers (C35, C40 & C60) automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation. Field Adjustable There are a number of field configurable, user adjustments for C Series controllers. C35 and C60's can only be set for 12 or 24 VDC operation. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries. DC Load Controller Mode When used as a load controller, the C Series (C40) will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable. DC Diversion Mode In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate microhydro and wind turbine systems which need a constant load. LED Status Indicator A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers (C35, C40 & C60). UL and cUL Listed C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers (C35, C40 & C60) are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements. LCD Digital Display (Optional) CM, CMR/50, CMR/100 -A back-lit meter which continuously displays: battery voltage, DC amperage, cumulative amp hours and amp hours since last reset. CM mounts on front of C Series, C35, C40 and C60, charge controllers. The remote meters CMR/50 and CMR/100 use simple telephone type plug-in connectors. 50 ft. (15 m) or 100 ft. (30 m) cable included. If used with a wind turbine, this will only measure voltage. Temperature Compensation BTS/15 or BTS/35 Monitors battery temperature and adjusts charging voltage for maximum performance. A 15 ft. (4.5 m) or 35 ft. (11 m) cable with standard telephone type connectors is included. Warranty Two years workmanship and materials. Specifications Model C35 C40 C60 Voltage Configurations 12 VDC 24 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC Maximum PV Array Open Circuit 55 VDC 55 VDC 125 VDC 125 VDC 125 VDC 55 VDC 55 VDC Charging/Load Current @ 25 °C 35 amps DC continuous 40 amps DC continuous 60 amps DC Continuous Recommended Breaker Size With Recommended Wire Size in Conduit 60 amps DC, #6 AWG 60 amps DC, #6 AWG 60 amps DC (100% continuous duty cycle), #6 AWG (90 °C rated) General Specifications Maximum Peak Current85 amps intermittently-electronically protectedMaximum Voltage Drop 0.30 volts -charge control mode Total Current Consumption While operating - 15 ma (typical), at idle - 3 ma (tare) Charge Regulation Method Solid state, 3-stage (Bulk, Absorption and Float) Pulse Width Modulation (PWM). Regulation Adjustment Settings Charge Control Mode Setup for: Lead Acid Battery 12 Volt Configuration: Float 12.5 - 14.5 VDC Bulk 13.0 - 15.0 VDC EQ +1 VDC above Bulk 24 Volt Configuration: Float 25.0 - 29.0 VDC Bulk 26.0 - 30.0 VDC EQ +2 VDC above Bulk 48 Volt Configuration: Float 50.0 - 58.0 VDC Bulk 52.0 - 60.0 VDC EQ +4 VDC above Bulk NiCad Type Battery (VDC above adjustment setting) Float or Bulk (add 2 VDC) Float or Bulk (add 4 VDC) Float or Bulk (add 8 VDC) Load Control Mode Low Voltage Reconnect (LVR) - Subtract 1 V (for 12 VDC systems), 2V (for 24 VDC systems), and 4 V (for 48 VDC systems) from the Bulk setting. Low Voltage Disconnect (LVD) - Subtract 2 V (for 12 VDC systems), 4 V (for 24 VDC systems), and 8V (for 48 VDC systems) from Float setting. Standard Features Status Indicator Multicolor LED indicates the operating/battery voltage status Low Voltage disconnect (Load Control Mode) User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a "grace" period. Equalization Charge (Charge Control Mode) User selectable manual or automatic equalization (every 30 days) Short Circuit Protection Fully electronically protected with auto-reset Field Adjustable Control Setpoints (test points provided for high accruacy) Two user adjustable voltage setpoints for control of loads or charging sources (settings retained if battery is disconnected) Options LCD Meter Panel (CM, CMR/25 CMR/50, CMR/100) Back-lit, 2-line, 32 character, alpha numeric liquid crystal display panel for remote (CMR/XX) or front mounting (CM) on the C Series controller. CMR/25 includes 25' (7.5 m) of cable. CMR/50 includes 50' (15 m) of cable, CMR/100 includes 100' (30 m) of cable. Displays: battery voltage, DC amperage, cumulative amp hours, amp hours since last reset. External Battery Temperature Sensor (BTS/15, BTS/35) Provides automatic adjustmentt of the charge control setpoints to the battery temperature. BTS/15 is supplied with 15' (4.5 m) of cable, BTS/35 cable length is 35' (11 m) Physical Enclosure Type Indoor, ventilated, powder-coated steel with 3/4" and 1" knockouts Specified Temperature Range 32 to 104 °F (0 to +40 °C) Allowed Temperature Range -67 to 167 °F (-55 to +75 °C) Altitude Limit (operating) 15,000 feet (5,000 meters) Altitude Limit (non-operating) 50,000 feet (16,000 meters) Dimensions (H x W x D) C35: 8" x 5" x 2.5" (20.3 cm x 12.7 cm x 6.35 cm) C40, C60: 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm) Mounting Vertical Wall Mount Weight (Controller only) C35: 2.5 lbs (1.2 kg), C40: 3.0 lbs (1.4 kg), C60: 3.0 lbs (1.4 kg) Weight (Shipping) C35: 3.0 lbs (1.4 kg), C40: 3.5 lbs (1.6 kg), C60: 3.5 lbs (1.6 kg) Certifications UL Listed to UL 1741 and CSA 22.2 107.1-95. CE Compliant, Designed to CTIK Standards. Warranty All C35, C40 and C60 controllers are warrantied for two years against defects in workmanship and materials. On Oct-22-13 at 17:27:47 PDT, seller added the following information: Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application FREE! Sellers: Add a FREE map to your listings. FREE! Hurricane Wind Power 2019Corporate America Today2019 Best Off-Grid Renewable Energy Product Supplier - USAUP TO 50% DISCOUNTSTOP BRANDSSee our other itemsPayment We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! Shipping We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.Returns If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. Thank you for visiting our Ebay store! Trace / Xantrex Auction for C60 Model only other models discussed for line comparison of PWM / Diversion load controllerShown with optional Meter see other auctions Xantrex C Series - C35, C40 & C60 Charge Controllers A Controller for Virtually any DC Charging Source The C40 has long been the mainstay of our charge controller line-up, its versatility and reliability have made it an industry standard. Now the C40 is joined by two companion controllers, the C35 and C60. All three of these fully solid state, microprocessor-driven controllers are UL and cUL listed. C Series controllers may be configured for PV battery charging, or DC load control or DC diversion operation. Whatever the charging source, a C Series controller is sure to meet your DC controller needs. Standard FeaturesSilent Microprocessor Control All C Series controllers (C35, C40 & C60) have a powerful microprocessor at their core which increases system performance and maximizes battery life. They are fully solid state and operate silently. PWM Charge Performance C Series controllers (C35, C40 & C60) all use Pulse Width Modulation (PWM) charging profiles which are designed to provide a full charge to your battery while, at the same time, minimize gassing which can shorten battery life. 3-Stage Battery Charging All C Series controllers (C35, C40 & C60) automatically initiate a 3-stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast-as-possible charging and extended battery life. An auto equalize mode can be easily switched off when the controller is used with sealed batteries. C Series controllers are factory set for solar PV battery charging operation. Field Adjustable There are a number of field configurable, user adjustments for C Series controllers. C35 and C60's can only be set for 12 or 24 VDC operation. The C40 may be configured for 12, 24 or 48 volt systems. Bulk and Float voltage set points are user adjustable which allows use with a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat. In addition, there are manually selectable settings for Nicad batteries. DC Load Controller Mode When used as a load controller, the C Series (C40) will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD (low voltage disconnect) and LVR (low voltage reconnect) set points are user adjustable. DC Diversion Mode In this mode, all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as water or space heaters. Diversion mode is used to regulate microhydro and wind turbine systems which need a constant load. LED Status Indicator A simple to read, multi-color LED indicates operating status and is standard on all C Series controllers (C35, C40 & C60). UL and cUL Listed C Series controllers are listed by UL to exacting UL 1741 and cUL CSA 22.2 107.1-95 standards. C Series controllers (C35, C40 & C60) are also CE compliant (European countries) and are designed to CTIK standards (Australia). Their current ratings are "real world" and do not have to be derated to comply with USA NEC 125% overcurrent requirements. LCD Digital Display (Optional) CM, CMR/50, CMR/100 -A back-lit meter which continuously displays: battery voltage, DC amperage, cumulative amp hours and amp hours since last reset. CM mounts on front of C Series, C35, C40 and C60, charge controllers. The remote meters CMR/50 and CMR/100 use simple telephone type plug-in connectors. 50 ft. (15 m) or 100 ft. (30 m) cable included. If used with a wind turbine, this will only measure voltage. Temperature Compensation BTS/15 or BTS/35 Monitors battery temperature and adjusts charging voltage for maximum performance. A 15 ft. (4.5 m) or 35 ft. (11 m) cable with standard telephone type connectors is included. Warranty Two years workmanship and materials. Specifications Model C35 C40 C60 Voltage Configurations 12 VDC 24 VDC 12 VDC 24 VDC 48 VDC 12 VDC 24 VDC Maximum PV Array Open Circuit 55 VDC 55 VDC 125 VDC 125 VDC 125 VDC 55 VDC 55 VDC Charging/Load Current @ 25 °C 35 amps DC continuous 40 amps DC continuous 60 amps DC Continuous Recommended Breaker Size With Recommended Wire Size in Conduit 60 amps DC, #6 AWG 60 amps DC, #6 AWG 60 amps DC (100% continuous duty cycle), #6 AWG (90 °C rated) General Specifications Maximum Peak Current85 amps intermittently-electronically protectedMaximum Voltage Drop 0.30 volts -charge control mode Total Current Consumption While operating - 15 ma (typical), at idle - 3 ma (tare) Charge Regulation Method Solid state, 3-stage (Bulk, Absorption and Float) Pulse Width Modulation (PWM). Regulation Adjustment Settings Charge Control Mode Setup for: Lead Acid Battery 12 Volt Configuration: Float 12.5 - 14.5 VDC Bulk 13.0 - 15.0 VDC EQ +1 VDC above Bulk 24 Volt Configuration: Float 25.0 - 29.0 VDC Bulk 26.0 - 30.0 VDC EQ +2 VDC above Bulk 48 Volt Configuration: Float 50.0 - 58.0 VDC Bulk 52.0 - 60.0 VDC EQ +4 VDC above Bulk NiCad Type Battery (VDC above adjustment setting) Float or Bulk (add 2 VDC) Float or Bulk (add 4 VDC) Float or Bulk (add 8 VDC) Load Control Mode Low Voltage Reconnect (LVR) - Subtract 1 V (for 12 VDC systems), 2V (for 24 VDC systems), and 4 V (for 48 VDC systems) from the Bulk setting. Low Voltage Disconnect (LVD) - Subtract 2 V (for 12 VDC systems), 4 V (for 24 VDC systems), and 8V (for 48 VDC systems) from Float setting. Standard Features Status Indicator Multicolor LED indicates the operating/battery voltage status Low Voltage disconnect (Load Control Mode) User selectable manual or automatic reconnection - includes warning flash before disconnect and provides a "grace" period. Equalization Charge (Charge Control Mode) User selectable manual or automatic equalization (every 30 days) Short Circuit Protection Fully electronically protected with auto-reset Field Adjustable Control Setpoints (test points provided for high accruacy) Two user adjustable voltage setpoints for control of loads or charging sources (settings retained if battery is disconnected) Options LCD Meter Panel (CM, CMR/25 CMR/50, CMR/100) Back-lit, 2-line, 32 character, alpha numeric liquid crystal display panel for remote (CMR/XX) or front mounting (CM) on the C Series controller. CMR/25 includes 25' (7.5 m) of cable. CMR/50 includes 50' (15 m) of cable, CMR/100 includes 100' (30 m) of cable. Displays: battery voltage, DC amperage, cumulative amp hours, amp hours since last reset. External Battery Temperature Sensor (BTS/15, BTS/35) Provides automatic adjustmentt of the charge control setpoints to the battery temperature. BTS/15 is supplied with 15' (4.5 m) of cable, BTS/35 cable length is 35' (11 m) Physical Enclosure Type Indoor, ventilated, powder-coated steel with 3/4" and 1" knockouts Specified Temperature Range 32 to 104 °F (0 to +40 °C) Allowed Temperature Range -67 to 167 °F (-55 to +75 °C) Altitude Limit (operating) 15,000 feet (5,000 meters) Altitude Limit (non-operating) 50,000 feet (16,000 meters) Dimensions (H x W x D) C35: 8" x 5" x 2.5" (20.3 cm x 12.7 cm x 6.35 cm) C40, C60: 10" x 5" x 2.5" (25.4 cm x 12.7 cm x 6.35 cm) Mounting Vertical Wall Mount Weight (Controller only) C35: 2.5 lbs (1.2 kg), C40: 3.0 lbs (1.4 kg), C60: 3.0 lbs (1.4 kg) Weight (Shipping) C35: 3.0 lbs (1.4 kg), C40: 3.5 lbs (1.6 kg), C60: 3.5 lbs (1.6 kg) Certifications UL Listed to UL 1741 and CSA 22.2 107.1-95. CE Compliant, Designed to CTIK Standards. Warranty All C35, C40 and C60 controllers are warrantied for two years against defects in workmanship and materials. On Oct-22-13 at 17:27:47 PDT, seller added the following information: Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application FREE! Sellers: Add a FREE map to your listings. FREE!
Price: 156 USD
Location: Roanoke, Virginia
End Time: 2024-09-16T01:17:08.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Xantrex
Power Source: Solar
Model: C60
MPN: C60